Published March 2008 | Version v1
Journal article

Phantom examination for reduction of radiation dose using new needle screen storage phosphor radiography and add beam filter in digital thoracic radiography on adolescents and larger children

  • 1. Klinikum der Friedrich-Schiller Univ., Jena (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

Description

Purpose: how much can the radiation dose be reduced in thoracic radiography on adolescents and larger children by using needle screen storage phosphor (NIP) radiography and add beam filtration? Materials and methods: a chest phantom with typical anatomical structures, pathological findings, added catheters, and simulated nodules, tumors, and calcifications was X-rayed digitally (DX-S, Agfa Healthcare) in posterior-anterior (p.a.) orientation with and without add beam filter. While keeping the voltage constant, the tube current time product was reduced gradually. In addition to LgM, the surface entrance dose (ED) and the dose area product (DAP) were measured by the Dosimax sensor and Kerma X-plus (both Wellhoefer). Five investigators evaluated the images for characteristics and critical features, pathological findings, and catheter recognizability. Results: the ED of the digital chest radiogram p.a. with 115 kV and 0.71 mAs was 27 μGy, the DAP 3.6 μGy x m2, the LgM value 1.56. This initial radiogram was able to be evaluated very well and conforms to the quality guidelines. The dose-reduced chest radiograms with the add beam filter Al 1.0 mm/Cu 0.1 mm were evaluated as sufficiently reduced to a dose of 63% of the initial dose, with the add beam filter Al 1.0 mm/Cu 0.2 mm reduced to 50% (0.52 mAs, DAP 1.82 μGy x m2, LgM 1.35). P.a. radiograms were able to be X-rayed on 115 kV with 0.52 mAs. (orig.)

Additional details

Additional titles

Original title (German)
Phantomuntersuchung zur Strahlendosisreduktion mittels neuer, auf Nadelstruktur basierender Speicherfolienradiografie und Zusatzfilterung in der Thoraxradiografie bei Jugendlichen und groesseren Kindern

Publishing Information

Journal Title
RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
Journal Volume
180
Journal Issue
3
Journal Page Range
p. 231-237
ISSN
1438-9029
CODEN
RFGNDO

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
39047513
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CARDIOVASCULAR DISEASES; CHEST; DIAGNOSIS; PHANTOMS; RADIATION DOSES
Descriptors DEC
BODY; DISEASES; DOSES; MOCKUP; STRUCTURAL MODELS