Comparative study between NCRP-49 and NCRP-147 methodologies for shielding calculus to fluoroscopy rooms

Description

The walls of a fluoroscopy room must be shielded to prevent unnecessary exposures to technicians and public individuals. Thus this dissertation aims to describe the methodologies contained in two documents which are references for the calculation of shielding those rooms. They are the National Council on Radiation Protection and Measurements Report No. 49 (NCRP Report No. 49) and No. 147 (NCRP Report No. 147), the latter being more recent publication. And based on such description was made a comparative study between the two methodologies, using for this, as a benchmark, spreadsheets computer program developed by Wolfram Mathematica 6. With that we could reach the final thickness of the barriers to a Standard Plan for a fluoroscopy room (provided by Siemens) and noted that the NCRP-49 presents a methodology with results more conservative. (author)

Files

43056335.pdf

Files (6.0 MB)

Name Size Download all
md5:eb016f017b42ed614278215ca7576496
6.0 MB Preview Download

Additional details

Additional titles

Original title (Portuguese)
Estudo comparativo entre as metodologias da NCRP-49 e da NCRP-147 para calculo de blindagem para salas de fluoroscopia

Publishing Information

Imprint Pagination
159 p.
Report number
INIS-BR--11221

INIS

Country of Publication
Brazil
Country of Input or Organization
Brazil
INIS RN
43056335
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Thesis
Descriptors DEI
COMPARATIVE EVALUATIONS; COMPUTER CALCULATIONS; FLUOROSCOPY; RADIATION PROTECTION; SHIELDS; THICKNESS; US NCRP; WALLS
Descriptors DEC
BIOMEDICAL RADIOGRAPHY; DIAGNOSTIC TECHNIQUES; DIMENSIONS; EVALUATION; MEDICINE; NATIONAL ORGANIZATIONS; NUCLEAR MEDICINE; RADIOLOGY; US ORGANIZATIONS