Published 1989 | Version v1
Report Restricted

A beam position monitor for low current dc beams

Description

The 4 GeV recirculating linac, CEBAF, if presently under construction and will produce a CW beam with average current between.1 and 200 μA. In order to measure beam position, the beam current will be amplitude modulated at a frequency of 10 MHz. The modulation is detected by an inductive loop type monitor with electronics sensitive only to the modulation frequency. The first test with beam from the CEBAF injector indicate that beam position can be measured with an accuracy of .1 mm at a modulated beam current of 1 μA. 1 ref., 6 figs., 1 tab

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02 - OSTI; 3 as DE89010342.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
DOE/ER/40150--62

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
20060743
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
BEAM CURRENTS; BEAM MONITORS; BEAM POSITION; CAMAC SYSTEM; CEBAF ACCELERATOR; DATA ACQUISITION SYSTEMS; SPECIFICATIONS
Descriptors DEC
ACCELERATORS; CURRENTS; LINEAR ACCELERATORS; MEASURING INSTRUMENTS; MONITORS

Optional Information

Notes
Paper copy only, copy does not permit microfiche production.
Secondary number(s)
CEBAF-PR--89-004.