Published September 1993 | Version v1
Journal article

A measurement of the effective delayed neutron fraction of the Westinghouse Idaho Nuclear Company Slab Tank Assembly using Rossi-α techniques

Creators

  • 1. Los Alamos National Lab., NM (United States)

Description

The effective delayed neutron fraction of a solution reactor fueled with highly enriched uranyl nitrate was measured using two Rossi-α techniques: the slope method and the Nelson number method. The average value of the effective delayed neutron fraction was measured to be 0.0147 ± 13%, which is significantly higher than the calculated value of 0.009. The discrepancy between the measured and the calculated value is not understood at this time, but it is suspected that the majority of the bias is associated with the measurement of the intrinsic neutron source strength

Additional details

Publishing Information

Journal Title
Nuclear Science and Engineering
Journal Volume
115
Journal Issue
1
Journal Page Range
p. 76-80.
ISSN
0029-5639
CODEN
NSENAO

INIS