The aim of this study was to create and test a new mice 3D-voxel phantom named DMBRA for mice and human first-estimation radiopharmaceutical dosimetry. Previously, the article reviews the state-of art in animal model development. Images from Digimouse CT database were used in the segmentation and on the generation of the voxelized phantom. Simulations for validation of the DMBRA model was performed at 0.015, 0.1, 0.5, 1 and 4 MeV photons with heart-source. Specific Absorbed Fractions (SAF) data were compared with literature data. The organ masses of DMBRA correlated well with existing models based on the same dataset; however, few small organ masses hold significant variations. The SAF data in most simulated cases were statistically equal to a significant level of 0.01 to the reference data. (author)

Additional details

Publishing Information

Journal Title
Brazilian Journal of Pharmaceutical Sciences (Online)
Journal Volume
53
Journal Issue
1
Journal Page Range
12 p.
ISSN
2175-9790