Published September 1980
| Version v1
Report
Open
Plasma density measurements using FM-CW millimeter wave radar techniques
Description
Modified FM-CW radar techniques using swept millimeter-wave oscillators are useful for determining when a particular density has been reached in a plasma. Narrowband measurements on the Princeton Large Torus (PLT) demonstrate the suitability of these techniques for controlling high-power auxiliary plasma heating systems. Broadband measurements using these same techniques are proposed, by which the density profile could be determined
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.Files
12572216.pdf
Files
(318.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:4dda8546d7e6870c7ecce98818d1310e
|
318.2 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 20 p.
- Report number
- PPPL--1690
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12572216
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- PLASMA DENSITY; PLASMA DIAGNOSTICS; PLASMA HEATING; PLT DEVICES; RADIOWAVE RADIATION; REFLECTION
- Descriptors DEC
- CLOSED PLASMA DEVICES; ELECTROMAGNETIC RADIATION; HEATING; RADIATIONS; THERMONUCLEAR DEVICES; TOKAMAK DEVICES