A high resolution HPGe coaxial detector γ spectroscopy

  • 1. Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

Description

A high resolution HPGe coaxial detector γ spectroscopy is developed, which consists of the HPGe coaxial detector (including a charge sensitive preamplifier), a gate integrate amplifier, a 8192 channel spectroscopy ADC in successive approximation method based on the bidirectional sliding scale principle, a 8192 channel multichannel buffer memory (MCB) et al.. Two types of the HPGe Coaxial Detector γ Spectroscopy GPY-1 and GPY-2 are developed. The energy resolution and long time stability of all systems are excellent

Part of:
Proceedings of 7. national conference on nuclear electronics and nuclear detection technology: Pt.1

Additional details

Publishing Information

Imprint Title
Proceedings of 7. national conference on nuclear electronics and nuclear detection technology: Pt.1
Imprint Pagination
359 p.
Journal Page Range
p. 178-182.

Conference

Title
7. national conference on nuclear electronics and nuclear detection technology.
Dates
6-12 Oct 1994.
Place
Lushan (China).

Optional Information