A study of ion chamber response compared with water calorimetry in a clinical 85 MEV proton beam

Description

As clinical proton therapy knew an increasing importance during the last years, the demand for accurate dosimetry of proton beams enhanced. Since the reference dosimetry quantity for proton dosimetry is absorbed dose and the reference material recently became water, a water calorimeter is very important as reference dosimetry instrument for proton beams. Using the water calorimeter constructed in Gent, we compared the absorbed dose based on it with ion chamber dosimetry in the 85 MeV proton beam of Louvain-la-Neuve. To first asses a potential impact of the high LET components in the modulated proton beam on the heat defect in water, a relative response study of the water calorimeter was performed using 3 different chemical systems: pure water, H2 saturated water and a 1 mM formate solution saturated with O2. By direct comparison to model calculations of the heat defect for these chemical systems, we were able to understand the measured calorimeter response as a function of accumulated dose. The absorbed dose resulting from this study was then compared with ionisation chamber dosimetry applying the ECHED protocol. The ratio of the calorimetric to the ionometric determined dose amounted to 0.974 ± 0.009. Measurements performed with ten ionisation chambers of five different types, yielded doses deviating no more than 1.1% from each other. They also showed a small influence of ion chamber wall thickness on the response, indicating that next to the contribution of the (Wair/e)p value for protons prescribed in the ECHED protocol, a small part of the above-mentioned discrepancy between the two dosimetry methods could possibly be attributed to chamber dependent parameters

Additional details

Identifiers

PII
0167814096806013;

Publishing Information

Journal Title
Radiotherapy and Oncology
Journal Volume
37
Journal Issue
3
Journal Page Range
p. S44
ISSN
0167-8140
CODEN
RAONDT

INIS

Country of Publication
Ireland
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
34044553
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CALORIMETRY; DOSE-RESPONSE RELATIONSHIPS; DOSIMETRY; IONIZATION CHAMBERS; LET; PROTON BEAMS
Descriptors DEC
BEAMS; ENERGY TRANSFER; MEASURING INSTRUMENTS; NUCLEON BEAMS; PARTICLE BEAMS; RADIATION DETECTORS

Optional Information

Copyright
Copyright (c) 1995 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.