Published July 1, 2006 | Version v1
Journal article

Experimental analysis of the electric field distribution in GaAs radiation detectors

  • 1. Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, Bratislava SK-812 19 (Slovakia)
  • 2. Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, Prague 2 CZ-12800 (Czech Republic)
  • 3. Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, Bratislava SK-841 04 (Slovakia)

Description

We describe the results of experimental studies of Liquid Encapsulated Czochralski (LEC) semi-insulating GaAs detectors with different contact areas. The detector active area spreading at different applied bias is proven by three various experiments. In the first, the scan of the detector electrode and adjacent area was performed using the 660 nm pulsed laser beam, with a spot diameter of 50 μm. The other experiments use the spectra measured by tested detectors, when irradiated by 241Am α source (5.48 MeV). The experiments show relation between bias voltage applied and the range of active detector area from the edge of the detector contact

Additional details

Identifiers

DOI
10.1016/j.nima.2006.01.092;
PII
S0168-9002(06)00215-4;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
563
Journal Issue
1
Journal Page Range
p. 187-191
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
7. international workshop on radiation imaging detectors
Acronym
IWORID 2005
Dates
4-7 Jul 2005
Place
Grenoble (France)

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.