Management of diagnostic x-ray radiation in developing countries

Creators

  • 1. Hiroshima International University, Hiroshima (Japan)

Description

The purpose of this study is to provide a simple, inexpensive, and effective method to prevent the scattering of x-ray radiation by using a lead apron in the x-ray rooms of developing countries. In developed countries, the scattering of x-ray radiation among patients and radiographers in diagnostic x-ray rooms has been minimized by various methods. However, in some developing countries, scattered x-ray radiation has not yet been adequately contained. The policy of As Law As Reasonably Achievable (ALARA) requires that patients who are waiting for their examinations must be protected from scattered x-ray radiation. However, from the author's experience, protection from scattered x-ray radiation in x-ray rooms is often insufficient in developing countries. In addition, major public hospitals in big cities are overwhelmed with patients because radiology resources in developing countries are concentrated in the big cities. Moreover, the situation is made worse by short working hours in public hospitals. Hours from 10 a.m. to 3 p.m. are typical. Because of the circumstances, radiographers, who are in a rush to finish all of the examinations within their normal working hours, sometimes allow patients to enter the x-ray rooms while they are waiting for their examinations. Chest and abdominal x-rays are the most common kinds of diagnostic x-ray examination in developing countries. Thus, in this study, anthropomorphic chest and abdominal phantoms were x-rayed for measuring the scattered x-ray radiation with and without protection using a 0.25mmPb lead apron at specific points from the anthropomorphic phantoms in the x-ray room. The lead apron was hung on a mobile apron-hanger and placed next to the anthropomorphic phantom. The scattered radiation dosimetry for chest x-rays proves that this simple method reduces scattered x-ray radiation to 15% at one-meter point and to almost 0% at the two-meter point from the anthropomorphic phantom in the x-ray room. Lead aprons are generally available in most developing countries, and the method described is simple and effective to reduce scattered x-ray radiation in the x-ray rooms. (author)

Part of:
IRPA-10. Proceedings of the 10th international congress of the International Radiation Protection Association on harmonization of radiation, human life and the ecosystem

Additional details

Publishing Information

Publisher
Japan Health Physics Society
Imprint Place
Tokyo (Japan)
Imprint Title
IRPA-10. Proceedings of the 10th international congress of the International Radiation Protection Association on harmonization of radiation, human life and the ecosystem
Imprint Pagination
1 v.
Journal Page Range
[6 p.]

Conference

Title
10. international congress of the International Radiation Protection Association
Acronym
IRPA-10
Dates
14-19 May 2000
Place
Hiroshima (Japan)

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
33000375
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ABDOMEN; CHEST; DIAGNOSTIC TECHNIQUES; LEAD; PHANTOMS; RADIATION PROTECTION; SCATTERING; SHIELDING; SPATIAL DOSE DISTRIBUTIONS; X-RAY EQUIPMENT
Descriptors DEC
BODY; ELEMENTS; EQUIPMENT; METALS; MOCKUP; RADIATION DOSE DISTRIBUTIONS; STRUCTURAL MODELS

Optional Information

Notes
This CD-ROM can be used for WINDOWS 95/98/NT, MACINTOSH; Acrobat Reader is included; Data in PDF format, No. P-7-6; 6 refs., 4 figs.