Published October 1991
| Version v1
Report
Restricted
Organizational processes and nuclear power plant safety
Creators
- 1. Pennsylvania State Univ., University Park (United States)
Description
The paper describes the effects organizational factors have on the risk associated with the operation of nuclear power plants. The described research project addresses three methods for identifying the organizational factors that impact safety. The first method consists of an elaborate theory-based protocol dealing with decision making procedures, interdepartmental coordination of activities, and communications. The second, known as goals/means/measures protocol, deals with identifying safey related goals. The third method is known as behaviorally anchored rating scale development. The paper discusses the importance of the convergence of these three methods to identify organizational factors essential to reactor safety
Files
Additional details
Publishing Information
- Imprint Title
- Transactions of the nineteenth water reactor safety information meeting
- Imprint Pagination
- 220 p.
- Journal Page Range
- p. 9.11-9.12.
- Report number
- NUREG/CP--0118
Conference
- Title
- 19. Nuclear Regulatory Commission (NRC) water reactor safety information meeting.
- Dates
- 28-30 Oct 1991.
- Place
- Bethesda, MD (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 23059457
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BWR TYPE REACTORS; EMERGENCY PLANS; MANAGEMENT; MITIGATION; PERFORMANCE; PWR TYPE REACTORS; REACTOR SAFETY; RESEARCH PROGRAMS; SCRAM; TIME DEPENDENCE; US NRC
- Descriptors DEC
- ENRICHED URANIUM REACTORS; NATIONAL ORGANIZATIONS; POWER REACTORS; REACTOR SHUTDOWN; REACTORS; SAFETY; SHUTDOWN; THERMAL REACTORS; US ORGANIZATIONS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-911079--.