Published March 1987
| Version v1
Journal article
Improvements of neutron activation techniques for the determination of fissile material concentrations
Description
Certain experimental improvements, as variable sample size and irradiation position, automation and flexibility in radiation detection, broaden the measurable concentration range, increase the possible rate and accuracy of analysis and enlarge the application range of home-made nuclear analyzer for fissile material analysis by delayed fission neutron counting and for short-lived multielement analysis by neutron activation gamma-ray spectrometry. Intercomparisons of results by various methods and laboratories show the need for regular checks of techniques to ensure reliable measurements. (author)
Additional details
Publishing Information
- Journal Title
- J. Radioanal. Nucl. Chem.
- Journal Volume
- 110
- Journal Issue
- 1
- Series
- J. Radioanal. Nucl. Chem. ;Articles.
- Journal Page Range
- 253-259
- ISSN
- 0236-5731
- CODEN
- JRNCD
Conference
- Title
- International symposium on nuclear analytical chemistry.
- Dates
- 5-7 Jun 1985.
- Place
- Halifax, Nova Scotia (Canada).
INIS
- Country of Publication
- Hungary
- Country of Input or Organization
- Hungary
- INIS RN
- 18084631
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AUTOMATION; COMPARATIVE EVALUATIONS; DELAYED NEUTRON ANALYSIS; FISSILE MATERIALS; FLUORESCENCE SPECTROSCOPY; GAMMA SPECTROSCOPY; MULTI-ELEMENT ANALYSIS; NEUTRON ACTIVATION ANALYSIS; OPTIMIZATION; SPECTROPHOTOMETRY; URANIUM; X-RAY FLUORESCENCE ANALYSIS
- Descriptors DEC
- ACTINIDES; ACTIVATION ANALYSIS; CHEMICAL ANALYSIS; ELEMENTS; EMISSION SPECTROSCOPY; EVALUATION; FISSIONABLE MATERIALS; MATERIALS; METALS; NONDESTRUCTIVE ANALYSIS; SPECTROSCOPY; X-RAY EMISSION ANALYSIS