PWR accident management realated tests: some Bethsy results
Description
The BETHSY integral test facility which is a scaled down model of a 3 loop FRAMATOME PWR and is currently operated at the Nuclear Center of Grenoble, forms an important part of the French strategy for PWR Accident Management. In this paper the features of both the facility and the experimental program are presented. Two accident transients: a total loss of feedwater and a 2'' cold leg break in case of High Pressure Safety Injection System failure, involving either Event Oriented - or State Oriented-Emergency Operating Procedures (EO-EOP or SO-EOP) are described and the system response analyzed. CATHARE calculation results are also presented which illustrate the ability of this code to adequately predict the key phenomena of these transients. (authors). 13 figs., 11 refs., 2 tabs
Availability note (English)
MF available from INIS under the Report Number.Files
25074104.pdf
Files
(446.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:abf1300ecef234216c7b952235442788
|
446.3 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 10 p.
- Report number
- CEA-CONF--11830
Conference
- Title
- 6. International Topical Meeting on Nuclear Reactors Thermal Hydraulics.
- Dates
- 5-8 Oct 1993.
- Place
- Grenoble (France).
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 25074104
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- C CODES; PWR TYPE REACTORS; REACTOR ACCIDENTS; TEST FACILITIES
- Descriptors DEC
- ACCIDENTS; COMPUTER CODES; ENRICHED URANIUM REACTORS; POWER REACTORS; REACTORS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS