Differences in particle size distributions collected by two wood dust samplers: preliminary findings

  • 1. Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro (ISPESL), Dipartimento Igiene del Lavoro, Laboratorio Polveri e Fibre, Monte Porzio Catone, RomE (Italy)
  • 2. Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro (ISPESL) Centro Ricerche Lamezia Terme, Laboratorio Polveri e Fibre, Lamezia Terme (Italy)

Description

The International Agency for Research on Cancer (IARC) classification of wood dust as carcinogenic to humans, and the threshold limit value (TLV) of 5 mg/m3 weighted over an 8-hour work day as defined by Italian legislation, have raised the issue of dust risk assessments in all woodworking environments. The aim is to characterize the particle size distribution for wood particles collected by two samplers used for collecting the inhalable fraction: the IOM sampler (Institute of Occupational Medicine, Edinburgh, Scotland) and the conical sampler also known in Italy as conetto. These two sampling heads were chosen mainly because the Italian conical sampler, used in the past for total dust sampling, is the most widely used by the Italian Prevention Services and analysis laboratories in general, whereas the IOM sampler was specifically designed to collect the inhalable fraction of airborne particles. The devices were placed side by side within the worker's breathing zone. In addition, another IOM sampler not connected to the personal sampling pump was placed on the same worker, thus functioning as a passive sampler capable of collecting projectile particles normally produced during processing. A Scanning Electron Microscope (SEM) coupled with energy dispersive X-ray spectrometry (EDAX) was used to count the number of particles collected on the sampling filters. The size of each particle identified by the SEM was determined by measuring its mean diameter. The SEM analysis revealed that the average size of the largest particles collected by the conetto sampler did not exceed 150 μm, whereas the size of particles collected by the IOM sampler was up to 350 μm. Indeed, the analysis of the filters of the passive IOM samplers showed that particles with mean diameters larger than 100 μm were collected, although the calculated percentage was very low (on average, approximately 1%). This does not mean that their gravimetric contribution is negligible; indeed, the weight of particles having a diameter larger than 100 μm present on the passive filters was 95% of the total

Additional details

Publishing Information

Journal Title
Prevention Today
Journal Volume
4
Journal Issue
3
Journal Page Range
p. 43-58
ISSN
1120-2971

INIS

Country of Publication
Italy
Country of Input or Organization
Italy
INIS RN
40049357
Subject category
S60: APPLIED LIFE SCIENCES;
Descriptors DEI
AIR POLLUTION MONITORING; CARCINOGENS; OCCUPATIONAL EXPOSURE; PARTICLE SIZE; PARTICULATES; RISK ASSESSMENT; SAMPLERS; WOOD
Descriptors DEC
EQUIPMENT; MONITORING; PARTICLES; SIZE