Published November 30, 1984 | Version v1
Journal article

Development and validation of a specific radioimmunoassay for PHI in plasma

  • 1. Bispebjerg Hospital, Copenhagen (Denmark). Dept. of Clinical Chemistry
  • 2. Copenhagen Univ. (Denmark). Herlev Hospital

Description

A sensitive and specific radioimmunoassay for the recently isolated neuropeptide with N-terminal histidine and C-terminal isoleucine amide (PHI) has been developed which can detect 3.0 pmol/l of the peptide in plasma. Labelling of PHI with 125I was performed by the chloramine T method. Non-specific interference in the assay was excluded by extraction of plasma with ethanol to a mean recovery of 82.4%. Plasma samples diluted parallel to the standard curve. The intra-assay and inter-assay coefficient of variation (CV) values at a level of 24.0 pmol/l were 6.3% and 13.1%, respectively. In 75 normal adults, the fasting PHI concentration ranged from 3.5-30.0 pmol/l with a mean of 14.2 pmol/l. In 235 children, the PHI concentration varied with age. Ingestion of a meal caused a rapid and short-lived increase in the PHI concentration. (Auth.)

Additional details

Publishing Information

Journal Title
Clin. Chim. Acta
Journal Volume
143
Journal Issue
3
Series
Clin. Chim. Acta.
Journal Page Range
183-192
ISSN
0009-8981