Published December 2008 | Version v1
Journal article

Poisson's Ratio Scanning Using Immersion Ultrasonic Testing

  • 1. Korea Science Academy, Busan (Korea, Republic of)
  • 2. Advanced Institute of Quality and Safety, Uiwang (Korea, Republic of)

Description

Poisson's ratio is one of elastic constants of elastic solids. However, it has not attracted attention due to its narrow range and difficult measurement. Transverse wave velocity as well as longitudinal wave velocity should be measured for nondestructive measurement of Poisson's ratio. Hard couplant for transverse wave prevents transducer from scanning over specimen. In the present work, a novel measurement of Poisson's ratio distribution was proposed. Immersion method was employed for the scanning over the specimen. Echo signals of normal beam longitudinal wave were collected. Transverse wave modes generated by mode conversion were identified. From transit time of longitudinal and transverse waves, Poisson's ratio can be determined without information of specimen thickness. This technique was demonstrated for aluminum and steel specimens

Additional details

Publishing Information

Journal Title
Journal of the Korean Society for Nondestructive Testing
Journal Volume
28
Journal Issue
6
Series
4 refs, 6 figs
Journal Page Range
p. 519-523
ISSN
1225-7842