Published September 1984 | Version v1
Report Restricted

Cost survey for radon daughter control by ventilation and other control techniques: radon emissions from underground uranium mines. Volume 2. Open file report, 30 September 1981-31 July 1984

Description

This study estimated (1) radon and radon daughter emissions from underground uranium mines; (2) the reduction in radon that would be released to the surface by using control techniques such as bulkheads, sealants, backfilling, and positive pressure ventilation; (3) the cost for radon and radon daughter removal from total exhaust air; and (4) total radon and radon daughter discharge for lower occupational exposure limits. For 13 large underground uranium mines, estimated yearly radon emissions from each mine ranged from 900 to 3,400 Ci. The estimated age of air emitted from the mines ranged from 11 to 37 min. Potential radon removal methods for the total mine exhaust were evaluated. The cost of these methods was prohibitive. Diurnal and seasonal changes may affect radon emission over short periods of time, but do not affect the total emissions over the long run. Radon and radon daughter emissions would be little changed by increased ventilation requirements needed to achieve lower occupational exposure limits. The concentrations in the exhaust would be lower, but the total release would be the same

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A06/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
102 p.
Report number
PB--85-152940/XAB

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
16077329
Subject category
S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
Descriptors DEI
AIR POLLUTION; CONTROL; COST; EMISSION; FORECASTING; MINING; RADON ISOTOPES; SYSTEMS ANALYSIS; URANIUM MINES; VENTILATION
Descriptors DEC
MINES; POLLUTION