Prior to start up of the Hunterston AGRs, concern was expressed, following laboratory tests, at the risk of breakaway oxidation in the 9% Cr steel used in the evaporator section of the boilers. To reduce the risk, it was recommended that the carburising potential of the (CO2) coolant during the critical stage of initial operation should be minimised. A coolant of 0.5% CO, 300 v.p.m. moisture, naturally occurring methane was, therefore, specified. Later changes in the coolant composition are discussed under the headings: target coolants; gas composition control; operating experience; monitoring (gas composition; graphite moderator and sleeves; fuel pin deposition; instrumented fuel stringers). (U.K.)