Published September 1975 | Version v1
Report Restricted

Mark I containment evaluation short term program: final report. Volume I. Program description and summary of conclusions

Description

An evaluation is presented of twenty-three Mark I containments subjected to the dynamic effects from the most probable pool dynamic loads induced by the postulated design basis accident. The evaluation herein verifies the Mark I containments will retain their structural integrity and will remain functional when subjected to the above loads, even though some of these loads were not explicitly included in the original containment design bases. One plant presently under construction will require minor modifications in order to assure structural integrity. (auth)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
BWR

Publishing Information

Imprint Pagination
v p.
Report number
NEDC--20989-1(Vol.1)

INIS

Optional Information

Notes
General Electric Co., San Jose, CA.