Scaling of AP containment wall heat removal
Creators
- 1. Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Thermal Engineering, Tsinghua University, Beijing (China)
- 2. INET of Tsinghua University, Beijing (China)
Description
To achieve the experimental scheme study of the AP containment, H2TS method was used to carry out the system-level scaling and the result showed the prominent distortion of area-volume ratio. Based on the basic criteria of volume-power ratio, the Bottom-Up scaling approach was used to analyze the interdependent relations for the coupled heat transfer on the containment wall. The Π group on AP containment heat removal was then obtained. Thermal conduction on the containment wall was taken as an example for scaling analyses. Schemes were then given to offset the scaling distortions. Relations of structure dimensions by scaling-down were finally listed. The current scaling technique could be applicable to the scaling of large scale and large space thermal-hydraulic phenomena. (authors)
Additional details
Identifiers
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 37
- Journal Issue
- 3
- Journal Page Range
- p. 94-98
- ISSN
- 0258-0926
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 50036373
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- CONTAINMENT; CURRENTS; REMOVAL; SCALING; THERMAL CONDUCTION; THERMAL HYDRAULICS
- Descriptors DEC
- ENERGY TRANSFER; FLUID MECHANICS; HEAT TRANSFER; HYDRAULICS; MECHANICS
Optional Information
- Notes
- 1 tab., 10 refs.; http://dx.doi.org/10.13832/j.jnpe.2016.03.0094