Journal article
Implementation of the VAMCIS monitoring system on PWRs in France and elsewhere
Creators
- 1. Electricite de France, Villeurbanne (France)
- 2. Merlin Gerin Provence, Senas (France)
Description
The VAMCIS system is designed to measure the leak rates inside pressurized water reactor (PWR) steam generators (SGs) continuously and accurately. It increases plant safety by providing reliable alarms in case of a steam generator tube rupture (SGTR). The paper discusses implementation on four-loop plants; available operating feedback; approval by EdF; cost/advantages approach; and use in other countries
Additional details
Publishing Information
- Journal Title
- Transactions of the American Nuclear Society
- Journal Volume
- 63
- Series
- Trans. Am. Nucl. Soc.
- Journal Page Range
- 404-405
- ISSN
- 0003-018X
- CODEN
- TANSA
Conference
- Title
- Annual meeting of the American Nuclear Society (ANS).
- Dates
- 2-6 Jun 1991.
- Place
- Orlando, FL (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 23036577
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCURACY; ALARM SYSTEMS; CONTAINMENT SYSTEMS; FRANCE; IMPLEMENTATION; LEAK DETECTORS; LEAKS; PERFORMANCE; PERFORMANCE TESTING; PRIMARY COOLANT CIRCUITS; PWR TYPE REACTORS; REACTOR MONITORING SYSTEMS; REACTOR SAFETY; RELIABILITY; SEISMIC EFFECTS; SHIELDING; STEAM GENERATORS
- Descriptors DEC
- BOILERS; CONTAINMENT; COOLING SYSTEMS; DEVELOPED COUNTRIES; ENRICHED URANIUM REACTORS; EUROPE; POWER REACTORS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; REACTORS; SAFETY; TESTING; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-910603--.