Published April 1992 | Version v1
Journal article

1 Molar concentration hydrofluoric acid effect at 400 C in the corrosion resistance of alloys containing nickel

  • 1. Comision Chilena de Energia Nuclear, Santiago (Chile)

Description

Corrosion rate for pure nickel, Inconel 600 and Monel alloys in a 1 Molar hydrofluoric acid solution at a 40 0 C temperature were determined. For contrasting purposes both SAE 304 SS and SAE 316 SS were included. As expected these Stainless Steels do not show good corrosion performance in the solution used. Several expressions correlating the weight and thickness loss v/s time were obtained. In the particular case of Monel, up to 2.021 hours, two expressions for the weight loss and three expressions for the thickness loss were obtained with a close to 1,0 correlation coefficient value. The Monel showed the best overall corrosion performance among the tested alloys. (author)

Additional details

Additional titles

Original title (Spanish)
Effecto del acido fluorhidrico en solucion 1 Ma 40

Publishing Information

Journal Title
Nucleotecnica
Journal Volume
12
Journal Issue
22
Journal Page Range
p. 9-15.
ISSN
0716-0054
CODEN
NUCLEQ