Published January 7, 2011 | Version v1
Journal article

Neutron computed tomography of rat lungs

  • 1. Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany)
  • 2. Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)
  • 3. Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany)
  • 4. Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)

Description

Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 μm, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)

Availability note (English)

Available from http://dx.doi.org/10.1088/0031-9155/56/1/N01

Additional details

Identifiers

DOI
10.1088/0031-9155/56/1/N01;
PII
S0031-9155(11)60547-7;

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
56
Journal Issue
1
Journal Page Range
p. N1-N10
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42036883
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; LUNGS; NEUTRONS; RATS
Descriptors DEC
ANIMALS; BARYONS; BODY; DIAGNOSTIC TECHNIQUES; ELEMENTARY PARTICLES; FERMIONS; HADRONS; MAMMALS; NUCLEONS; ORGANS; RESPIRATORY SYSTEM; RODENTS; TOMOGRAPHY; VERTEBRATES