Neutron computed tomography of rat lungs
Creators
- 1. Institute for Computational Mechanics at Technische Universitaet Muenchen, 85747 Garching (Germany)
- 2. Department of Anesthesiology, Section for Experimental Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)
- 3. Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM-II) and Fakultaet fuer Physik E21 at Technische Universitaet Muenchen, 85748 Garching (Germany)
- 4. Department of Anesthesiology, University Medical Center Freiburg, 79106 Freiburg (Germany)
Description
Using conventional methods, three-dimensional imaging of the lung is challenging because of the low contrast between air and tissue and the large differences in dimensions between various pulmonary structures. The small distal airway structures and the high air-to-tissue ratio of lung tissue require an imaging technique which reliably discriminates between air and water. The objective of this study was to assess whether neutron computed tomography would satisfy such a requirement. This method utilizes the unique characteristic of neutrons of directly interacting with the atomic nucleus rather than being scattered by the atomic shell. Neutron computed tomography was tested in rats and allowed differentiation of larger lung structures (e.g., lobes) and distal airways. Airways could be identified reliably down to the sixth bronchial generation, in some cases even down to the tenth generation. The lung could be stabilized for sufficiently long exposure times to achieve an image resolution of 50-60 μm, which is the current physical resolution limit of the neutron computed tomography facility. Neutron computed tomography allowed excellent lung imaging without the need for additional tissue preparation or contrast media. The enhanced structural resolution obtained by applying this new research technique may improve understanding of lung physiology and respiratory therapy. (note)
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/56/1/N01Additional details
Identifiers
- DOI
- 10.1088/0031-9155/56/1/N01;
- PII
- S0031-9155(11)60547-7;
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 56
- Journal Issue
- 1
- Journal Page Range
- p. N1-N10
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42036883
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- COMPUTERIZED TOMOGRAPHY; LUNGS; NEUTRONS; RATS
- Descriptors DEC
- ANIMALS; BARYONS; BODY; DIAGNOSTIC TECHNIQUES; ELEMENTARY PARTICLES; FERMIONS; HADRONS; MAMMALS; NUCLEONS; ORGANS; RESPIRATORY SYSTEM; RODENTS; TOMOGRAPHY; VERTEBRATES