Critique of Hanford Waste Vitrification Plant off-gas sampling requirements

Description

Off-gas sampling and monitoring activities needed to support operations safety, process control, waste form qualification, and environmental protection requirements of the Hanford Waste Vitrification Plant (HWVP) have been evaluated. The locations of necessary sampling sites have been identified on the basis of plant requirements, and the applicability of Defense Waste Processing Facility (DWPF) reference sampling equipment to these HWVP requirements has been assessed for all sampling sites. Equipment deficiencies, if present, have been described and the bases for modifications and/or alternative approaches have been developed

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE96008178; NTIS; US Govt. Printing Office Dep.

Files

27057215.pdf

Files (1.4 MB)

Name Size Download all
md5:54b615aaf9cbba54e36bc2abd97e47a8
1.4 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
67 p.
Report number
PNNL--11061

Optional Information

Contract/Grant/Project number
Contract AC06-76RL01830
Funding organization
USDOE, Washington, DC (United States).