Published 1966 | Version v1
Miscellaneous Open

Safety shutdowns and failures of the RA reactor equipment

Creators

  • 1. Institut za nuklearne nauke 'Boris Kidric', Vinca, Belgrade (Yugoslavia)

Description

This report is an attempt of statistical analysis of the failures occurred during RA reactor operation. A list of failures occurred on the RA equipment during 1965 is included. Failures were related to the following systems: dosimetry system (22%), safety and control system (7%), heavy water system (2%), technical water (4%), helium system (2%), measuring instruments (30%), transport, ventilation, power supply systems (32%). A review of safety shutdowns from 1962 to 1966 is included as well, as a comparison with three similar reactors. Although the number of events used for statistical analysis was not adequate, it has been concluded that RA reactor operation was stable and reliable

Files

38013828.pdf

Files (779.8 kB)

Name Size Download all
md5:28512620adbbe7e65c9e22226cc132ef
779.8 kB Preview Download
Part of:
Proceedings of 2. Yugoslav symposium on reactor physics, Part 2, Herceg Novi (Yugoslavia), 27-29 Sep 1966

Additional details

Additional titles

Original title (Serbian)
Sigurnosna zaustavljanja i kvarovi opreme na reaktoru RA

Publishing Information

Imprint Place
Herceg Novi (Yugoslavia)
Imprint Title
Proceedings of 2. Yugoslav symposium on reactor physics, Part 2, Herceg Novi (Yugoslavia), 27-29 Sep 1966
Imprint Pagination
157 p.
Journal Page Range
19 p.
Report number
INIS-RS--0180

Optional Information

Notes
6 refs, 5 figs, 8 tabs Imprint:52 refs, 46 figs, 22 tabs;2. Jugoslovenski simpozijum iz reaktorske fizike, Deo 2, Herceg Novi (Yugoslavia), 27-29 Sep 1966