Validation of the GEANT4 Monte Carlo code in the Tunisian Gamma irradiation facility
Creators
- 1. National Center for Nuclear Sciences and Technologies, 2020 Sidi Thabet, Tunisia. (Tunisia)
Description
This work describes a complete Monte Carlo study of the Tunisian gamma irradiation facility (CNSTN) using the GEANT4 CERN's code. The study focused on the optimization of the absorbed dose distribution inside the irradiation cell, with and without product. For this purpose, 32 different points at the middle plane of the source rack, 29 positions along Z axis and 7 critical points, were carried out using PMMA dosimeters. Then, to achieve a given bulk density, boxes loaded with ''dummy'' product, were used. Simulated and experimental results are compared and good agreement is observed. It is shown that Monte Carlo simulation improves process understanding, predicts absorbed dose distributions and calculates dose uniformity within product
Additional details
Publishing Information
- Imprint Title
- Proceedings of the eight national conference on research in physics
- Imprint Pagination
- 410 p.
- Journal Page Range
- p. 399
Conference
- Title
- 8. national conference on research in physics
- Dates
- 20-23 Dec 2005
- Place
- Elkantaoui-Sousse (Tunisia)
INIS
- Country of Publication
- Tunisia
- Country of Input or Organization
- Tunisia
- INIS RN
- 38017882
- Subject category
- S99: GENERAL AND MISCELLANEOUS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- COMPUTERIZED SIMULATION; G CODES; GAMMA RADIATION; IRRADIATION PLANTS; MONTE CARLO METHOD; TUNISIA; VALIDATION
- Descriptors DEC
- AFRICA; ARAB COUNTRIES; CALCULATION METHODS; COMPUTER CODES; DEVELOPING COUNTRIES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; NUCLEAR FACILITIES; RADIATIONS; SIMULATION; TESTING