Published August 2019 | Version v1
Journal article

Sensitivity analysis of source intensity and time bin size for the Rossi-alpha method in a numerical reactor model

  • 1. Department of Nuclear Engineering, Ulsan National Institute of Science and Technology, 50, UNIST-gil, Eonyang-eup, Ulju-gun, Ulsan, 44919 (Korea, Republic of)

Description

Highlights: • Sensitivity analyses were performed to determine an optimized source intensity for a numerical reactor model. • Sensitivity analyses were performed to determine an optimized time bin size for a numerical reactor model. • When the source intensity is greater than 105 s−1, the Rossi-alpha method has errors of 200 pcm or less. • When the source intensity is smaller than 105 s−1, the change in accuracy was shown tobe greater. • When the time bins were smaller than 10−5 s, the Rossi-alpha method showed errors than 200 pcm. • When the time bins were greater than 10−5 s, the change in accuracy was shown to be greater. • In this study, setting the neutron source intensity to 105 s−1 or higher and the time bin unit to 10−5 s or less provides converged accuracy and standard deviation. - Abstract: Until now, various studies focusing on subcriticality measurements have been conducted using the Rossi-alpha method. However, no guidelines have been provided for the source intensity and time bin size of the Rossi-alpha analysis. In this study, sensitivity analyses were performed to determine an optimized source intensity and time bin size for a numerical reactor model. Using the MCNP6 Monte Carlo code, fission count signals in the fuel region were tallied 50 times with different random seeds in real-time mode. These signals were applied to the Rossi-alpha method as detector signals. The estimated keff values were compared to the reference keff values generated by the MCNP6 criticality calculation. As a result of the sensitivity test for the neutron source intensity, the Rossi-alpha method has errors of 200 pcm or less when the source intensity is greater than 105 s−1. It is shown that the standard deviations of 50 analyses are converged when the source intensity is greater than 105 s−1. At the same time, as a result of the sensitivity test for the time bin size, the Rossi-alpha method shows errors less than 200 pcm when the time bin size is smaller than 10−5 s. It is shown that the standard deviations of 50 analyses are converged when the time bins are smaller than 10−5 s. For the numerical reactor model in this study, the threshold time bin size was set to 10−5 s. However, it generally depends on the neutron generation time of the problem. Thus, it is recommended to set the neutron source intensity to 105 s−1 or higher and the time bins to the time of the neutron generation or less when the Rossi-alpha method is applied to subcriticality measurements in nuclear reactor cores.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.anucene.2019.02.040

Additional details

Identifiers

DOI
10.1016/j.anucene.2019.02.040;
PII
S0306454919301094;

Publishing Information

Journal Title
Annals of Nuclear Energy (Oxford)
Journal Volume
130
Journal Page Range
p. 157-163
ISSN
0306-4549
CODEN
ANENDJ

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
51012854
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
ACCURACY; CRITICALITY; ERRORS; FISSION; MONTE CARLO METHOD; NEUTRON SOURCES; REACTOR CORES; REACTOR OPERATION; ROSSI ALPHA METHOD; SENSITIVITY ANALYSIS; SIGNALS
Descriptors DEC
CALCULATION METHODS; NUCLEAR REACTIONS; OPERATION; PARTICLE SOURCES; RADIATION SOURCES; REACTOR COMPONENTS; REACTOR LIFE CYCLE