Published 1985 | Version v1
Book

Sizing and image reconstruction of flaws by mechanized ultrasonic inspection system

  • 1. Ishikawajima-Harima Heavy Industries CO., Yokohama (Japan)

Description

Periodic in-service inspection is required to assure the reliability to a nuclear power plant in operation. Recently, many studies have been done on the reliability of ultrasonic inspection using partial full-scale mockups. This paper evaluates the sizing and image reconstruction capability of an automated ultrasonic inspection system that analyzes flaw data, based on ASME Code Section XI. The 161 mm thick SA 533B CL.1 specimens with artificial flaws on the clad/unclad surface were examined using a mechanized inspection device. The experimental test result shows that conventional ultrasonic inspection technique is capable of flaw detection but that additional effort will be necessary for flaw sizing. 4 refs

Part of:
Proceedings of the 7. International conference on non destructive evaluation in nuclear industry

Additional details

Publishing Information

Publisher
COFREND.
Imprint Place
Paris (France)
Imprint Title
Proceedings of the 7. International conference on non destructive evaluation in nuclear industry
Imprint Pagination
466 p.
Journal Page Range
p. 117-121.

Conference

Title
7. International conference on non destructive evaluation in nuclear industry.
Dates
28 Jan - 1 Feb 1985.
Place
Grenoble (France).