Published January 1, 2018
| Version v1
Journal article
The in-process control of PVC sheath of a double core cable
Creators
- 1. National Research Tomsk Polytechnic University, Tomsk (Russian Federation)
Description
In this work the possibility of the sheath hermiticity testing by measuring of the cable capacity per unit length variation during spark testing is considered. The research object is 2×0.75 HO3VVH2-F cable. According to the physical modelling it is proved that such defect of sheath as pinhole through the whole thickness of sheath can be registered for the test length 10 cm with test voltage frequencies 1kHz and 10kHz. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1757-899X/289/1/012006Additional details
Identifiers
Publishing Information
- Journal Title
- IOP Conference Series. Materials Science and Engineering (Online)
- Journal Volume
- 289
- Journal Issue
- 1
- Journal Page Range
- [6 p.]
- ISSN
- 1757-899X
Conference
- Title
- 6. International Conference on Modern Technologies for Non-Destructive Testing
- Dates
- 9-14 Oct 2017
- Place
- Tomsk (Russian Federation)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 52067868
- Subject category
- S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CABLES; COMPUTERIZED SIMULATION; ELECTRIC POTENTIAL; LENGTH; PROCESS CONTROL; PVC; TESTING; THICKNESS
- Descriptors DEC
- CONTROL; DIMENSIONS; ORGANIC COMPOUNDS; POLYMERS; SIMULATION