Published November 2008 | Version v1
Miscellaneous Open

On the absorbed dose determination method in high energy photon beams

  • 1. National Institute for Lasers, Plasma and Radiation Physics (NILPRP), Bucharest, Romania (Romania)
  • 2. National Institute of Physics and Nuclear Engineering Horia Hulubei C Vocational Training Center in the Nuclear Field, Bucharest, Romania (Romania)

Description

The absorbed dose determination method in water, based on standards of air kerma or exposure in high energy photon beams generated by electron with energies in the range of 1 MeV to 50 MeV is presented herein. The method is based on IAEA-398, AAPM TG-51, DIN 6800-2, IAEA-381, IAEA-277 and NACP-80 recommendations. The dosimetry equipment is composed of UNIDOS T 10005 electrometer and different ionization chambers calibrated in air kerma method in a Co60 beam. Starting from the general formalism showed in IAEA-381, the determination of absorbed dose in water, under reference conditions in high energy photon beams, is given. This method was adopted for the secondary standard dosimetry laboratory (SSDL) in NILPRP-Bucharest

Files

40081112.pdf

Files (380.1 kB)

Name Size Download all
md5:c9e2e0ef82712c4496c81ae637165b77
380.1 kB Preview Download
Part of:
Proceeding of the Sixth Nuclear and Particle Physics Conference (NUPPAC-2007)

Additional details

Publishing Information

Imprint Title
Proceeding of the Sixth Nuclear and Particle Physics Conference (NUPPAC-2007)
Imprint Pagination
642 p.
Journal Page Range
p. 485-494
Report number
INIS-EG--214

Conference

Title
6. Conference on Nuclear and Particle Physics
Acronym
NUPPAC 07
Dates
17-21 Nov 2007
Place
Luxor (Egypt)