Published June 2013 | Version v1
Journal article

The study on influencing factors of control rod position measurement accuracy in PWR nuclear power station

  • 1. Chinese Nuclear Power Manager Company Factory Two, Zhejiang, Haiyan (China)

Description

The rod position system of pressurized-water reactor nuclear power station primarily displays the positions of control rods in the reactor. The article summarizes the design characters and objections of this detector through analyzing the influence factors on measurement precision of rod position. At the same time, some improvements to the system are presented according to these objections. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
33
Journal Issue
6
Journal Page Range
p. 712-716, 661
ISSN
0258-0934

Optional Information

Notes
3 figs., 1 tab., 1 ref.