Hybrid dosimetry: Feasibility of mixing angulated and parallel needles in planning prostate brachytherapy
Creators
- 1. Departments of Radiation Oncology, James P. Wilmot Cancer Center, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, New York 14642 (United States)
- 2. Departments of Urology, James P. Wilmot Cancer Center, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, New York 14642 (United States)
- 3. Departments of Radiology, James P. Wilmot Cancer Center, University of Rochester Medical Center, 601 Elmwood Avenue, Rochester, New York 14642 (United States)
- 4. School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore)
Description
Pubic arch interference (PAI) often caused inadequate prostate coverage during transperineal brachytherapy using all parallel needles. In this paper, a hybrid implantation approach is presented in which additional angulated needles can be used to avoid PAI. This approach can be applied in prostate brachytherapy using a robotic assisted device. To examine the feasibility of this approach, volume data from three prostate seed implant patients were selected, which represent small, medium, and large prostates. As the blocking area was artificially increased simulating pubic arch overlap, the dosimetry outcomes and ratio of number of angulated needles to the total number of needles were analyzed. The hybrid dosimetry broke down when blocking is over 42%. As the percent of blocking increased, the ratio of the number of angulated needles to the total number of needles increased, while the dosimetry outcomes only had a slight trend of worsening. When close to the breakdown point, the dosimetry outcomes worsen drastically. Therefore, for moderate PAI the hybrid dosimetry is feasible
Additional details
Identifiers
- DOI
- 10.1118/1.2188075;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 33
- Journal Issue
- 5
- Journal Page Range
- p. 1192-1198
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 37078762
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BRACHYTHERAPY; DOSIMETRY; PATIENTS; PROSTATE; RADIATION SOURCE IMPLANTS
- Descriptors DEC
- BODY; GLANDS; IMPLANTS; MALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATION SOURCES; RADIOLOGY; RADIOTHERAPY; THERAPY
Optional Information
- Notes
- (c) 2006 American Association of Physicists in Medicine