Published 1986 | Version v1
Book

Surveillance of part-length shield assemblies and axially zoned fuel in H.B. Robinson Unit 2 Cycle 10

  • 1. Carolina Power and Light Co., Raleigh, NC 27602

Description

Part-length Shield Assemblies and natural urania blanketed fuel installed in H.B. Robinson Unit 2, Cyle 10, required the development of 3-D analytic factors to process flux maps. The procedure used a combination of 2-D fine mesh and 3-D nodal simulator calculations to derive the factors. With care in application, the procedure proved adequate for monitoring the Cycle 10 core; however, the need for developing more accurate 3-D methods for highly segmented PWR cores was indicated

Additional details

Publishing Information

Publisher
American Nuclear Society.
Imprint Place
La Grange Park, IL (USA)
ISBN
0-89448-123-1
Imprint Title
Proceedings of the topical meeting on advances in fuel management
Journal Page Range
p. 75-80.

Conference

Title
Topical meeting on advances in fuel management.
Dates
2-5 Mar 1986.
Place
Pinehurst, NC (USA).