Multidetector computed tomography (MDCT) evaluation of myocardial viability: intraindividual comparison of monomeric vs. dimeric contrast media in a rabbit model
Creators
- 1. University Hospital, RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany)
- 2. RWTH Aachen University, Applied Medical Engineering, Helmholtz Institute, Aachen (Germany)
- 3. RWTH Aachen University, Department of Diagnostic Radiology, Aachen (Germany)
- 4. Bayer-Schering Pharma AG, Berlin (Germany)
Description
To evaluate the influence of different types of iodinated contrast media on the assessment of myocardial viability, acute myocardial infarction (MI) was surgically induced in six rabbits. Over a period of 45 min, contrast-enhanced cardiac MDCT (64 x 0.6 mm, 80 kV, 680mAseff.) was repeatedly performed using a contrast medium dose of 600 mg iodine/kg body weight. Animals received randomized iopromide 300 and iodixanol 320, respectively. Attenuation values of healthy and infarcted myocardium were measured. The size of MI was computed and compared with nitroblue tetrazolium (NBT)-stained specimen. The highest attenuation differences between infarcted and healthy myocardium occurred during the arterial phase with 140.0±3.5 HU and 141.0±2.2 HU for iopromide and iodixanol, respectively. For iodixanol the highest attenuation difference on delayed contrast-enhanced images was achieved 3 min post injection (73.5 HU). A slightly higher attenuation difference was observed for iopromide 6 min after contrast medium injection (82.2 HU), although not statistically significant (p=0.6437). Mean infarct volume as measured by NBT staining was 33.5%±13.6%. There was an excellent agreement of infarct sizes among NBT-, iopromide- and iodixanol-enhanced MDCT with concordance-correlation coefficients ranging from ρ(c)= 0.9928-0.9982. Iopromide and iodixanol both allow a reliable assessment of MI with delayed contrast-enhanced MDCT. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-008-1150-3Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 19
- Journal Issue
- 2
- Journal Page Range
- p. 290-297
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 40031271
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARDIOVASCULAR SYSTEM; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; MYOCARDIUM; RABBITS; VIABILITY
- Descriptors DEC
- ANIMALS; BODY; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; EVALUATION; HEART; MAMMALS; MUSCLES; ORGANS; TOMOGRAPHY; VERTEBRATES