Published May 2021 | Version v1
Journal article

Accurate real-time monitoring of high particulate matter concentration based on holographic speckles and deep learning

  • 1. Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang 37673, South (Korea, Republic of)
  • 2. Division of Biomedical Engineering, College of Engineering, Jeonbuk National University, 567 Baekje-daero, Deokjin-gu, Jeonju-si, Jeollabuk-do 54896, South (Korea, Republic of)

Description

Highlights: • High PM concentration was predicted from holographic speckles by using deep learning. • Image processing for holographic speckles was demonstrated. • Air sampling time was reduced to few seconds without procedure of air intake. • The Holo-SpeckleNet showed better robustness against overfitting than CNN. Accurate real-time monitoring of particulate matter (PM) has emerged as a global issue due to the hazardous effects of PM on public health and industry. However, conventional PM monitoring techniques are usually cumbersome and require expensive equipments. In this study, Holo-SpeckleNet is proposed as a fast and accurate PM concentration measurement technique with high throughput using a deep learning based holographic speckle pattern analysis. Speckle pattern datasets of PMs for a wide range of PM concentrations were acquired by using a digital in-line holography microscopy system. Deep autoencoder and regression algorithms were trained with the captured speckle pattern datasets to directly measure PM concentration from speckle pattern images without any air intake device and time-consuming post image processing. The proposed technique was applied to predict various PM concentrations using the test datasets, optimize hyperparameters, and compare its performance with a convolutional neural network (CNN) algorithm. As a result, high PM concentration values can be measured over air quality index of 150, above which human exposure is unhealthy. In addition, the proposed technique exhibits higher measurement accuracy and less overfitting than the CNN with a relative error of 7.46 ± 3.92%. It can be applied to design a compact air quality monitoring device for highly accurate and real-time measurement of PM concentrations under hazardous environment, such as factories or construction sites.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.jhazmat.2020.124637

Additional details

Identifiers

DOI
10.1016/j.jhazmat.2020.124637;
PII
S0304389420326273;

Publishing Information

Journal Title
Journal of Hazardous Materials
Journal Volume
409
Journal Page Range
vp.
ISSN
0304-3894
CODEN
JHMAD9

Optional Information

Copyright
Copyright (c) 2020 Elsevier B.V. All rights reserved.