Published July 2001 | Version v1
Journal article

Utility of QGS for 201Tl electrocardiogram-gated SPECT in cardiac function evaluations

  • 1. Sapporo Kosei Hospital (Japan)

Description

QGS (quantitative gated SPECT) was applied to 201Tl SPECT, whose images are inferior to those of Tc SPECT, and its utility was evaluated. More specifically, the cardiac function index was calculated by QGS, and local wall motion was evaluated visually. Accuracy was assessed by comparison with left ventriculography. The subjects were 29 patients (21 males, 8 females; 6 with myocardial infarction, 18 with stenocardia, 2 with pericardial disease, 3 with other heart diseases) who had undergone myocardial scintigraphy and left ventriculography between February and May, 2000. 201Tl (74 or 111 MBq) was administered to all patients. The resting image was obtained 10 minutes later, and the delayed image during loading was obtained 4 hours later. The conditions for acquiring the images were as follows. Two detectors were arranged at a 90-degree angle in the form of an L. The 180 degrees from 45 degrees right anterior oblique (RAO) to 45 degrees left posterior oblique (LPO) were divided into 30 sections at 6-degree intervals, and the image in each section was acquired for 60 seconds. The matrix was 64 x 64. As a cardiac function index, the left ventricular ejection function (LVEF) obtained by electrocardiogram-gated SPECT (QGS-EF) at the rest (14 cases) and the QGS-EF on the delayed images (15 cases) were compared with the LVEF determined by left ventriculography (LVG-EF). There was an excellent positive correlation between the data obtained by two methods, with a correlation coefficient of r=0.93 (y=1.04x-0.04). Most of the difference between the values fell within two standard deviations, and the error was in the clinically allowable range. There was no significant difference between the correlation coefficient at rest and during loading or between the cases that showed an obvious defect on the image and those that did not. The local wall motion of the left ventricle was visually evaluated in five stages in two directions (RAO, 30 degrees, and LAO, 60 degrees). The motion scores in the QGS image and the LVG image agreed in 124 (67.4%) of 184 areas. A difference of one level in the score was shown in 42 areas (22.8%) and a difference of 2 or more levels in the score in 18 areas (9.8%). The results demonstrated that evaluation of myocardial blood-flow functions by 201Tl electrocardiogram gated SPECT is possible. (K.H.)

Additional details

Publishing Information

Journal Title
Hokkaido Hoshasen Gijutsu Zasshi
Journal Volume
61
Journal Page Range
p. 47-53
ISSN
0912-0327