Measurements of bone mineral density of the proximal femur by two commercially available dual energy X-ray absorptiometric systems
- 1. Glostrup Sygehus, Copenhagen (Denmark). Dept. of Clinical Chemistry
Description
Two dual energy X-ray absorptiometric (DXA) instruments have recently become commercially available for local bone densitometry: the QDR-1000 (Hologic Inc.) and the DPX (Lunar Radiation Corp.). We report the precision, influence of femoral, rotation, correlation and agreement of bone mineral measurements of the proximal fermur by these two instruments. In vitro (femur phantom) short-term precision was 1.1%-3.5%, and the long-term precision was 1.2%-3.8%. In vivo (groups of 10 premenopausal and 10 postmenopausal women) short-term precision of duplicate measurements was 1.6%-4.7%, and long-term precision was 1.9%-5.5%. Overall, the precision for Ward's triangle was over 3% and that for the femoral neck and trochanter, 2%-3%. Rotation of the femur phantom produced a statistically significant change in the bone mineral density (BMD) of the femoral neck. Within a clinically relevant range of femoral rotation (20deg inward rotation ±5deg) the coefficient of variation (CV%) increased by a mean factor of 1.1-1.4. Although the correlation (r<0.9) between BMD measurements of the proximal femur by the DPX and QDR-1000 in 30 postmenopausal women was high, there was lack of agreement between the two instruments. We found no statistically significant differences between the right and left femur in 30 postmenopausal women. A bilateral femur scan took a mean total time of about 22 min. We conclude that with the introduction of DXA instruments, the precision of bone mineral measurments of the proximal femur has improved. However, for comparability between commercially available DXA instruments, it might be advantageous if units were standardized. (orig.)
Additional details
Publishing Information
- Journal Title
- European Journal of Nuclear Medicine
- Journal Volume
- 19
- Journal Issue
- 1
- Series
- Eur. J. Nucl. Med.
- Journal Page Range
- 41-46
- ISSN
- 0340-6997
- CODEN
- EJNMD
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 23014547
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABSORPTION SPECTRA; ACCURACY; BIOMEDICAL RADIOGRAPHY; BONE TISSUES; FEMUR; MINERALS; OSTEODENSITOMETRY; PATIENTS; PHANTOMS; ROTATION; X-RAY RADIOGRAPHY; X-RAY TUBES
- Descriptors DEC
- ANIMALS; BODY; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; ELECTRON TUBES; EQUIPMENT; MAMMALS; MAN; MEDICINE; MOCKUP; ORGANS; PRIMATES; SKELETON; SPECTRA; STRUCTURAL MODELS; TISSUES; VERTEBRATES; X-RAY EQUIPMENT