Published February 1998 | Version v1
Report Open

Review of application code and standards for mechanical and piping design of HANARO fuel test loop

Description

The design and installation of the irradiation test facility for verification test of the fuel performance are very important in connection with maximization of the utilization of HANARO. HANARO fuel test loop was designed in accordance with the same code and standards of nuclear power plant because HANARO FTL will be operated the high pressure and temperature same as nuclear power plant operation conditions. The objective of this study is to confirm the propriety of application code and standards for mechanical and piping of HANARO fuel test loop and to decide the technical specification of FTL systems. (author). 18 refs., 8 tabs., 6 figs

Availability note (English)

Available from INIS in electronic form and/or on microfiche .

Files

29025631.pdf

Files (2.0 MB)

Name Size Download all
md5:d1ae25b97fc4720615896fd05827d6d8
2.0 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
159 p.
Report number
KAERI/TR--951/98