Published October 2015 | Version v1
Miscellaneous Open

Dose verification by OSLDs in the irradiation of cell cultures

  • 1. Ce. De. Te. Centro Especializado en Terapia Radiante, Viamonte 1861, C1056 Buenos Aires (Argentina)
  • 2. Comision Nacional de Energia Atomica, Departamento de Micro y Nanotecnologia, Av. Gral. Paz 1499, 1650 San Martin, Buenos Aires (Argentina)

Description

The determination of value of irradiation dose presents difficulties when targets are irradiated located in regions where electronic equilibrium of charged particle is not reached, as in the case of irradiation -in vitro- of cell lines monolayer-cultured, in culture dishes or flasks covered with culture medium. The present study aimed to implement a methodology for dose verification in irradiation of cells in culture media by optically stimulated luminescence dosimetry (OSLD). For the determination of the absorbed dose in terms of cell proliferation OSL dosimeters of aluminum oxide doped with carbon (Al2O3:C) were used, which were calibrated to the irradiation conditions of culture medium and at doses that ranged from 0.1 to 15 Gy obtained with a linear accelerator of 6 MV photons. Intercomparison measurements were performed with an ionization chamber of 6 cm3. Different geometries were evaluated by varying the thicknesses of solid water, air and cell culture medium. The results showed deviations below 2.2% when compared with the obtained doses of OSLDs and planning system used. Also deviations were observed below 3.4% by eccentric points of the irradiation plane, finding homogeneous dose distribution. Uncertainty in the readings was less than 2%. The proposed methodology contributes a contribution in the dose verification in this type of irradiations, eliminating from the calculation uncertainties, potential errors in settling irradiation or possible equipment failure with which is radiating. It also provides certainty about the survival curves to be plotted with the experimental data. (Author)

Files

47032311.pdf

Files (426.9 kB)

Name Size Download all
md5:89db03fab123e7d95180e4aa0ce66c83
426.9 kB Preview Download

Additional details

Additional titles

Original title (Spanish)
Verificacion de dosis mediante OSLDs, en la irradiacion de cultivos celulares

Publishing Information

Publisher
Sociedad Mexicana de Irradiacion y Dosimetria
Imprint Place
Mexico, D. F. (Mexico)
Imprint Pagination
8 p.
Report number
INIS-MX--2975

Conference

Title
15. International Symposium on Solid State Dosimetry
Original Conference Title
15. Conferencia Internacional sobre Dosimetria de Estado Solido
Dates
26-30 Sep 2015
Place
Leon, Guanajuato (Mexico)