Low-level determination of plutonium by gamma and L x-ray spectroscopy

Description

we have developed an analytical method for detection of 239Pu in aqueous samples at concentrations as low as 10-10 M. This nuclear counting technique utilizes the uranium L X-rays, which follow the alpha decay of plutonium. Because L X-rays are specific for the element and not for the individual isotopes, the isotopic composition of the plutonium sample must be known. The counting efficiency in the 11--23 keV range is determined from a plutonium standard, and the concentration of the sample is then calculated from the L X-ray count and the isotopic composition. The total L X-ray count is corrected for possible contributions from other radionuclides present as impurities by measuring the low-energy gamma spectrum for each contaminant to establish specific photon/X-ray ratios. The ratios are important when 241Pu and 242Pu are measured, because the respective decay chain members produce non-U L X-rays. This new method can replace the use of labor-intensive radiochemical separation techniques and elaborate activation methods for analysis of 239Pu in aqueous samples. It is also applicable for assaying plutonium in liquid wastes that pose possible hazards to the environment

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE92017375; NTIS; INIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number
LBL--30617

Conference

Title
International topical conference on methods and applications of radioanalytical chemistry II (MARC-2).
Dates
21-27 Apr 1991.
Place
Kona, HI (United States).

Optional Information

Contract/Grant/Project number
Contract AC03-76SF00098
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
TWS-LBL--04-91-02; CONF-910422--10.