Features of plasma sprayed beryllium armor for the ITER first wall

  • 1. Sandia National Laboratories, United States Department of Energy, National Nuclear Security Administration, Albuquerque, NM (United States)
  • 2. Los Alamos National Laboratory, Los Alamos, NM (United States)

Description

Two water-cooled mockups with CuCrZr heat sinks and plasma sprayed beryllium (PS Be) armor, 5 and 10mm thick respectively, were fabricated at Los Alamos National Laboratory and thermally cycled at Sandia at 1 and 2MW/m2. The castellated surface of the CuCrZr mechanically locked the armor. The resulting PS Be morphology controlled cracking during thermal cycling. Post test examinations showed transverse cracks perpendicular to the surface of the armor that would relieve thermal stresses but not degrade heat transfer. The mockups and two others previously produced for the European Fusion Development Agreement had somewhat porous armor, with a thermal conductivity estimated to be about 1/4 that of fully dense beryllium, due to the low (600-650oC) substrate temperature during deposition specifically requested by EFDA to avoid subsequent heat treating of CuCrZr. Some melting of the armor was expected and observed in the tests

Additional details

Identifiers

DOI
10.1016/j.jnucmat.2007.03.244;
PII
S0022-3115(07)00600-9;

Publishing Information

Journal Title
Journal of Nuclear Materials
Journal Volume
367-370
Journal Page Range
p. 1325-1329
ISSN
0022-3115
CODEN
JNUMAM

Conference

Title
12. international conference on fusion reactor materials
Acronym
ICFRM-12
Dates
7-12 Dec 2005
Place
Santa Barbara, CA (United States)

Optional Information

Copyright
Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.
Contract/Grant/Project number
Contract DE-AC04-94AL85000