Published December 1980 | Version v1
Report Restricted

Experimental facility for containment sump reliability studies (Generic Task A-43)

Description

On July 3, 1979, Sandia National Laboratories (Sandia) contracted the Alden Research Laboratory (ARL) to conduct tests on unresolved safety issues associated with containment sump performance during the recirculation mode (Generic Task A-43). This report describes the test facility constructed and completed under Phase I, Task III of the contract. Sump performance is determined through the observation of vortex formation in the main tank and the measurement of swirl, pressure gradient, and entrained air in the suction pipes. The use of electrically operated valves and a sophisticated data acquisition system, with computer interface, allows the test flow parameters to be set and test data to be taken (with the exception of vortex observations) from a single central office

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A04/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Augmented title (English)
PWR; BWR

Publishing Information

Imprint Pagination
72 p.
Report number
ALO--132