Optimization of the radiological protection in fluoroscopy: determination of the diagnosis reference levels
Creators
- 1. Universidade do Estado, Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas
- 2. Institut fuer Strahlenschutz, Neuherberg (Germany). GSF Forschungszentrum
Description
This work was performed to investigate the actual exposure levels of the patients submitted to fluoroscopic procedures (with and without image intensifiers) in diagnostic radiology. The data will be useful for a baseline in the establishment of local reference levels for fluoroscopic procedures, as recommended by the European Commission and IAEA. At present time there are not internationally accepted definitions for references levels for fluoroscopic complex procedures. Dose-area product (DAP) meters were employed in a pilot survey expressing the radiation exposures in terms of this quantity. This class of instrumentation has not been employed in Brazil yet. Parameters recorded were radiographic technique, fluoroscopy time, number of images, fluoroscopic and radiographic field sizes and DAPs. For fluoroscopy practice, a reference parameters set is recommended, instead of one diagnostic reference level. High patient exposures were found, then attention is called about the significant effect on collective dose. Monitoring of patient exposure, optimizing the radiation protection and establishing quantitative assessments of the exposition to the population in Brazil in this kind of procedure is very important. (author)
Additional details
Additional titles
- Original title (Portuguese)
- Otimizacao da protecao radiologica em fluoroscopia: determinacao de niveis de referencia de diagnostico
Publishing Information
- Imprint Title
- Proceedings of the 5. Regional congress on radiation protection and safety; 2. Iberian and Latin American Congress on Radiological Protection Societies; Regional IRPA Congress
- Imprint Pagination
- [1735 p.]
- Journal Page Range
- [6 p.]
Conference
- Title
- 5. Regional congress on radiation protection and safety; 2. Iberian and Latin American Congress on Radiological Protection Societies; Regional IRPA Congress
- Dates
- 29 Apr - 4 May 2001
- Place
- Recife, PE (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 33067386
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- FLUOROSCOPY; IMAGE INTENSIFIERS; LEVELS; OPTIMIZATION; PERSONNEL MONITORING; RECOMMENDATIONS; STANDARDS
- Descriptors DEC
- BIOMEDICAL RADIOGRAPHY; DIAGNOSTIC TECHNIQUES; MEDICINE; MONITORING; NUCLEAR MEDICINE; RADIATION MONITORING; RADIOLOGY
Optional Information
- Notes
- 15 refs., 4 tabs. Imprint:Published only in CD-ROM. This electronic proceedings requires the Adobe Acrobat Reader 4.05 (included on this CD) and PC (at least 486 CPU) running Windows 95/98NT