Published April 2017
| Version v1
Journal article
Introduction of the radiation environment monitoring system in Sanmen nuclear power plant
- 1. ZheJiang Province Environmental Radiation Monitoring Center, Radiation Monitoring Technical Center of Ministry of Environmental Protection, Hangzhou (China)
Description
Objective: To monitor the radiation environment around Sanmen Nuclear Power Plant. Methods: By the continuous monitoring of gamma radiation dose rate and method of sample collection and analysis. Results: Ten monitoring stations were set up to monitor the radiation environment, including data collection, storage, transmission and analysis module. Conclusion: At present, the system is stable and reliable. (authors)
Additional details
Publishing Information
- Journal Title
- Chinese Journal of Radiological Health
- Journal Volume
- 26
- Journal Issue
- 2
- Journal Page Range
- p. 230-232, 233
- ISSN
- 1004-714X
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 50069840
- Subject category
- S54: ENVIRONMENTAL SCIENCES; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- DOSE RATES; ENVIRONMENT; GAMMA RADIATION; NUCLEAR POWER PLANTS; RADIATION DOSES; RADIATION MONITORING; RADIATION MONITORS
- Descriptors DEC
- DOSES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MEASURING INSTRUMENTS; MONITORING; MONITORS; NUCLEAR FACILITIES; POWER PLANTS; RADIATIONS; THERMAL POWER PLANTS
Optional Information
- Notes
- 2 figs., 1 tab., 5 refs.