A comparison of technetium-99m diphosphonate and strontium-87m scans of more than 50 patients with a hip prosthesis is presented. A newly-developed Sr-87m generator, using yttrium-87, is described. The preliminary results render that technetium gives 10-25% false-positive and no false-negative scans. Strontium scans possess a good correlation with the true situation, when dealing with the possibility of a loosened prosthesis. In order to avoid unnecessary operations a strontium scan should follow a positive technetium scan. (Auth.)

Additional details

Additional titles

Original title (Dutch)
Toepassing van Sr-87m naast Tc-99m-MDP voor diagnostiek bij patieenten, verdacht van los zittende heupprothesen