Published 1976 | Version v1
Report Open

Picosecond trigger system useful in mode-locked laser pulse measurements

  • 1. Strasbourg-1 Univ., 67 (France). Centre de Recherches Nucleaires
  • 2. CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Service de Physique Atomique

Description

A highly sensitive tunnel diode trigger useful in temporal intensity build-up measurements of mode-locked lasers has been developed; the device reduces notably the time walk due to the lack of repeatability in intensity of the laser output. The performance of the trigger have been established by means of a GHz wideband-0.1V/cm sensitive real-time oscilloscope and of an image converter camera having a picosecond resolution: the experimental results show that a variation of the amplitude of the laser pulse train of a factor 5 leads to a time jitter of less than 30 ps (Auth.)

Availability note (English)

MF available from INIS under the Report Number.

Files

8301981.pdf

Files (1.3 MB)

Name Size Download all
md5:5b3e64684e43a16fafb0bd0aab5c074d
1.3 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
22 p.
Report number
CRN-CNPA--76-21