Published August 1997
| Version v1
Book
Spark Source Mass Spectrometry for trace constituents determination in thoria
Creators
- 1. Fuel Chemistry Division, Bhabha Atomic Research Centre, Mumbai (India)
Description
Spark Source Mass Spectrometry is selected for the determination of trace constituents in thoria which is an important nuclear material because of its high sensitivity down to ppb levels
Additional details
Publishing Information
- Publisher
- Indian Society for Mass Spectrometry.
- Imprint Place
- Mumbai (India)
- Imprint Title
- ISMAS bulletin cum souvenir
- Imprint Pagination
- 135 p.
- Journal Page Range
- p. 93-94.
Conference
- Title
- 8. ISMAS workshop on mass spectrometry.
- Dates
- 4-9 Aug 1997.
- Place
- Mumbai (India).
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 29033482
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DOPED MATERIALS; GRAPHITE; MASS SPECTRA; MASS SPECTROSCOPY; QUANTITATIVE CHEMICAL ANALYSIS; SENSITIVITY; SPARK MASS SPECTROMETERS; THORIUM OXIDES; TRACE AMOUNTS
- Descriptors DEC
- ACTINIDE COMPOUNDS; CARBON; CHALCOGENIDES; CHEMICAL ANALYSIS; ELEMENTS; MASS SPECTROMETERS; MATERIALS; MEASURING INSTRUMENTS; NONMETALS; OXIDES; OXYGEN COMPOUNDS; SPECTRA; SPECTROMETERS; SPECTROSCOPY; THORIUM COMPOUNDS