The purpose was the optimization of the radiation protection during examinations with 18F-FDG, The immediate validation by the D.G.S.N.R., the results of dosimetry (h.p.10 = 12 μ sievert (average value/ technician / day for 6 patients) demonstrate the efficiency of the implemented means. From the very beginning, the installation of a PET-scanner requires a multidisciplinary conception. This essential thought contributes to an optimal radiation protection of the entire personnel of the service. (N.C.)

Additional details

Additional titles

Original title (French)
Tepscan et radioprotection

Publishing Information

Journal Title
Journal de Radiologie (Paris)
Journal Issue
no.10t.87
Journal Page Range
p. 1484
ISSN
0221-0363
CODEN
JORADF

Conference

Title
54. French days of radiology; 27. french speaking days organised by the French Society of Radiology
Original Conference Title
54. journees francaise de radiologie. 27. journees Francophones organisees par la Societe Francaise de Radiologie
Dates
21-25 Oct 2006
Place
Paris la Defense (France)