Published September 2014 | Version v1
Miscellaneous

Evaluation of fuel integrity for seawater intrusion event at Hamaoka 5

  • 1. Japan Chubu Electric Power Co., Inc., Omaezaki, Shizuoka (Japan)
  • 2. Global Nuclear Fuel-Japan Co., Ltd., Yokosuka, Kanagawa (Japan)
  • 3. Nippon Nuclear Fuel Development Co., Ltd., Oarai, Ibaraki (Japan)

Description

At Unit 5 of Hamaoka NPS (Hamaoka 5), approximately five metric tons of seawater flowed into the reactor core due to failure of the main condenser tubes as a result the nuclear fuels were exposed to the high-temperature water containing high concentrate of chloride ion for a short period. In order to evaluate the integrity of these fuels, visual inspection, oxide film thickness measurement and crud analysis on the fuel cladding tubes were performed at the spent fuel pool. The pool-side inspection results revealed that there was no unusual appearance on the fuel components. The laboratory material tests using irradiated and unirradiated specimens implied that no crevice corrosion happened in the fuel assembly components under the water chemistry conditions simulating seawater intrusion. (author)

Part of:
Proceedings of 2014 water reactor fuel performance meeting/ top fuel / LWR fuel performance meeting (WRFPM 2014)

Additional details

Publishing Information

Imprint Title
Proceedings of 2014 water reactor fuel performance meeting/ top fuel / LWR fuel performance meeting (WRFPM 2014)
Imprint Pagination
784 p.
Journal Page Range
3 p.

Conference

Title
2014 water reactor fuel performance meeting/ top fuel / LWR fuel performance meeting
Acronym
WRFPM 2014
Dates
14-17 Sep 2014
Place
Sendai, Miyagi (Japan)

Optional Information

Notes
Available as CD-ROM Data in PDF format, Paper ID: fullpaper100142.pdf; 4 figs., 5 tabs.