Published 1979 | Version v1
Book

Comparison of the rat and mouse model for monitoring the radiochemical purity of Tc-99m human serum albumin

  • 1. Radiation Protection Bureau, Ottawa, Ontario

Description

Kits from 4 manufacturers were reconstituted according to package insert instructions. The radiochemical purity of each preparation was assessed by in vitro techniques prior to biological distribution studies in rats and mice. Tissues of interest were blood and liver. Analysis of variance (at p = 0.05) indicated that there was a significant difference between the tissue distribution results for rats and mice. Also, there was a significant difference between preparations based on the blood results for either rats or mice but not the liver results. Only the blood results reflected the in vitro test values

Additional details

Publishing Information

Publisher
Society of Nuclear Medicine, Inc.
Imprint Place
New York, NY
Imprint Title
Radiopharmaceuticals. II
Journal Page Range
p. 25-31.

Conference

Title
2. international symposium on radiopharmaceuticals.
Dates
18 - 23 Mar 1979.
Place